| Height | 826 mm |
| PERFORMANCE DATA / HEATING MODE | |
| Heating (A7° C ; W35° C) : | |
| Nominal Heating Capacity | 8.10 kW |
| COP | 4.53 |
| Maximum Heating Capacity | 13.7 kW |
| Minimum Heating Capacity | 2.2 kW |
| SCOP | 4.82 kW |
| Třída energetické účinnosti | A+++ |
| Heating (A-7° C ; W35° C) : | |
| Nominal Heating Capacity | 4.86 kW |
| COP | 2.91 |
| Heating (A7° C ; W55° C) : | |
| Nominal Heating Capacity | 7.06 kW |
| COP | 2.31 |
| SCOP | 3.44 |
| Třída energetické účinnosti A+ | A++ |
| PERFORMANCE DATA/ COOLING MODE | |
| Chlazení (A35 °C; W7 °C): | |
| Nominal Cooling Capacity | 6.3 kW |
| EER | 3.18 kW |
| Maximum Cooling Capacity | 8.1 kW |
| Minimum Cooling Capacity | 2.5 kW |
| SEER | 5.45 |
| Cooling (A35 °C; W18 °C) : | |
| Nominal Cooling Capacity | 8.7 kW |
| EER | 4.21 |
| ELECTRICAL DATA : | |
| Supply voltage | 230 / 1 / 50 V / ph / Hz |
| Maximum absorbed power ( Unit without heating element ) | 3.9 kW |
| Maximum absorbed power ( Unit with 6kW heating element ) | 9.9 kW |
| REFRIGERANT CONNECTIONS | |
| Refrigerant type | R32 (GWP 675) |
| Refrigerant Load | 2.0 kg |
| Operating range | -25 to +43 |
| INDOOR UNIT : | |
| Model | RHP 9 SI 1P HE6 NV |
| Kód | 423822 |
| Šířka | 501 mm |
| Hloubka | 321 mm |
| Hmotnost | 41 kg |
| Indoor unit protection degree | IPX2 |
| Sound power level | 41 dB |
| Sound pressure 1m | 30 dB(A) |
| Circulation pump performance | |
| Model of the pump | PARA 25-130/8 |
| Available pump head (A7;W35) | 58 kPa |
| OUTDOOR UNIT : | |
| Model | RHP ATW 9 SO 1P NV |
| Kód | 423832 |
| Výška | 996 mm |
| Šířka | 940 mm |
| Hloubka | 340 mm |
| Hmotnost | 65 kg |
| Outdoor unit protection degree | IPX4 |
| Sound power level Heating | 61 dB |
| Sound pressure 1m Heating | 50 dB(A) |
| Sound power level Cooling | 59 dB |
| Sound pressure 1m Cooling | 48 dB(A) |
| Kompresor | Twin Rotary compressor with oil separator |
| HYDRAULIC CONNECTIONS : | |
| Nominal flow rate in heating (A7/W35 °C) | 23.2 L / min |
| Nominal flow rate in cooling. (A35/W18 °C) | 25.0 L / min |
| Safety valve | 3 bar |
| Maximum permissible temperature in the system | 65 °C |
| Expansion vessel capacity of the system | 8 l |
| Internal pressure losses | 18 kPa |
| Minimum system water content | 40 l |
| Minimum water flow rate to close the differential pressure | 13.9 L / min |
| % in relation to the nominal flow rate | 60 % |
| Minimum water flow to open the differential pressure | 12 L / min |
| % in relation to the nominal flow rate | 21 % |
| Hydraulic connections | 1''G |
* Povinná pole